AMIA Annu Symp Proc ; 2022: 244-253, 2022.
Artículo en Inglés | MEDLINE | ID: covidwho-20236828

RESUMEN

The COVID-19 pandemic presented challenges to the healthcare system while catalyzing the adoption of virtual care. The need for remote assessment and real-time monitoring of physiological vital signs has driven towards a need for virtual care solutions. This paper presents the outcome of a multidisciplinary collaboration to ensure clinical usability of a remote contactless sensing technology, VitalSeer, and to help close gaps between emerging technologies and clinical practice. The paper describes the user-centric data-driven clinical approach to address the needs as identified by clinical experts through the iterative and agile development cycle. It highlights findings from preliminary studies to validate proof-of-concept VitalSeer's adoptability, accessibility and usability. The studies on volunteers demonstrated the accuracy of VitalSeer's heart rate model at a low MAE of 0.74 (bpm) and a RMSE of 1.2 bpm, below the threshold of clinical grade contact-based sensors. The paper concludes with a discussion on the technology implications in emergency medicine and community care.


Asunto(s)
COVID-19 , Pandemias , COVID-19/epidemiología , Atención a la Salud , Humanos , Tecnología , Signos Vitales
2.
AMIA ... Annual Symposium proceedings. AMIA Symposium ; 2022:244-253, 2022.
Artículo en Inglés | EuropePMC | ID: covidwho-1940020

RESUMEN

The COVID-19 pandemic presented challenges to the healthcare system while catalyzing the adoption of virtual care. The need for remote assessment and real-time monitoring of physiological vital signs has driven towards a need for virtual care solutions. This paper presents the outcome of a multidisciplinary collaboration to ensure clinical usability of a remote contactless sensing technology, VitalSeer, and to help close gaps between emerging technologies and clinical practice. The paper describes the user-centric data-driven clinical approach to address the needs as identified by clinical experts through the iterative and agile development cycle. It highlights findings from preliminary studies to validate proof-of-concept VitalSeer’s adoptability, accessibility and usability. The studies on volunteers demonstrated the accuracy of VitalSeer’s heart rate model at a low MAE of 0.74 (bpm) and a RMSE of 1.2 bpm, below the threshold of clinical grade contact-based sensors. The paper concludes with a discussion on the technology implications in emergency medicine and community care.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA